SICHARGE UC Dispenser
4.3 Connection
①
UC150 charging station
②
PE conductor
③
AC connection cable
④
Ethernet cable connection for external communication
⑤
Ethernet cable connection for internal communication between charging station and dispenser
⑥
AC AUX cable to charge point
⑦
DC cable to charge point
⑧
Global DC shutdown loop (only possible with GEN2 Dispenser)
Figure 4-2
Connection of four dispensers
Connecting the power supply cable
Connecting the PE conductor
No.
1
Remove the sheath of the power supply cable to approximately 8 cm in length
2
Select a wire end ferrule for the appropriate conductor cross-section
3
Strip the insulation from the end of the conductor so that the remaining insulation extends up to
the ferrule
4
Properly attach the wire end ferrule to the conductor end
5
Insert the wire end ferrule into the terminal strip of the ground connection
6
Check the connection of the PE conductor to the PE terminal
7
Document the characteristics of the cable used for the installation
•
Type of cable
•
Cable cross section
•
Cable length
32
Checklist item
Installation and Commissioning Checklist for SICHARGE UC
Product Information, 03/2023, A5E52548271-AA
P
F
N/A
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐
☐