SCALANCE M874, M876
Operating Instructions
02/2023
C79000-G8976-C331-12
Preface
Safety notices
Security recommendations
Description of the device
Installation and removal
Connecting up
Maintenance and cleaning
Troubleshooting
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE M874

  • Page 1 Preface Safety notices Security recommendations SIMATIC NET Description of the device Industrial Remote Communication Remote Networks Installation and removal SCALANCE M874, M876 Connecting up Operating Instructions Maintenance and cleaning Troubleshooting Technical specifications Dimension drawings Approvals 02/2023 C79000-G8976-C331-12...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface Purpose of the operating instructions These operating instructions contain information with which you can install and connect the SCALANCE device correctly. The configuration and the integration of the device in a network are not described in these instructions. Scope of validity These operating instructions cover the following products: Product Description...
  • Page 4 Preface You will find the article numbers for the Siemens products of relevance here in the following catalogs: • SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI • SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 •...
  • Page 5 (https:// support.industry.siemens.com/cs/ww/en/view/84922825) SIMATIC NET manuals You will find SIMATIC NET manuals on the Internet pages of Siemens Industry Online Support: • using the search function: Link to Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/) Enter the entry ID of the relevant manual as the search item.
  • Page 6 Check regularly for new firmware/software versions or security updates and apply them. After the release of a new version, previous versions are no longer supported and are not maintained. Error/fault If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not permitted. Decommissioning Shut down the device properly to prevent unauthorized persons from accessing confidential data in the device memory.
  • Page 7 You will find license conditions in the following documents on the supplied data medium: • OSS_Scalance-M-800-S615_86.pdf SIMATIC NET glossary The SIMATIC NET glossary describes terms that may be used in this document. You will find the SIMATIC NET glossary in the Siemens Industry Online Support at the following address: 50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045) SCALANCE M874, M876...
  • Page 8 Preface SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 9: Table Of Contents

    Table of contents Preface ..............................3 Safety notices ............................13 Security recommendations........................15 Security recommendations....................15 Available services....................... 19 Description of the device ........................23 Product characteristics ....................... 23 Device views ........................24 3.2.1 SCALANCE M874 ....................... 24 3.2.2 SCALANCE M876 ....................... 25 Scope of delivery .......................
  • Page 10 Table of contents Connecting up ............................. 53 Safety when connecting up....................53 Power supply ........................59 Grounding ......................... 60 Digital input/output ......................61 Antennas ........................... 63 Ethernet port ........................66 SIM card ..........................67 Replacing the PLUG......................68 Maintenance and cleaning ........................71 Troubleshooting...........................
  • Page 11 Table of contents 10.2.2 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 ................... 113 10.2.3 Radio Equipment Regulations 2017 .................. 114 10.2.3.1 Protection of health and safety ..................114 10.2.3.2 EMC..........................114 10.2.3.3 Efficient use of the radio spectrum ...................
  • Page 12 Table of contents SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 13: Safety Notices

    Safety notices CAUTION To prevent injury and damage, read the manual before using the device. Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation"...
  • Page 14 Safety notices SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 15: Security Recommendations

    • For data transmission via a non-secure network, use an encrypted VPN tunnel (IPsec, OpenVPN). • Check the user documentation of other Siemens products that are used together with the device for additional security recommendations. • Using remote logging, ensure that the system protocols are forwarded to a central logging server.
  • Page 16 • Verify certificates based on the fingerprint on the server and client side to prevent "man in the middle" attacks. Use a second, secure transmission path for this. • Before sending the device to Siemens for repair, replace the current certificates and keys with temporary disposable certificates and keys, which can be destroyed when the device is returned.
  • Page 17 Implementation Information Disclosure Vulnerability (for example, BEAST). • Ensure that the latest firmware version is installed, including all security-related patches. You can find the latest information on security patches for Siemens products at the Industrial Security (https://www.siemens.com/industrialsecurity) or ProductCERT Security Advisories (https://www.siemens.com/cert/en/cert-security-advisories.htm) website.
  • Page 18 Security recommendations 2.1 Security recommendations • Use the authentication and encryption mechanisms of SNMPv3 if possible. Use strong passwords. • Configuration files can be downloaded from the device. Ensure that configuration files are adequately protected. Configuration files can be password protected during download. You enter passwords on the WBM page "System >...
  • Page 19: Available Services

    Security recommendations 2.2 Available services • If a secure alternative is available for a protocol, use it. The following protocols provide secure alternatives: – SNMPv1/v2 → SNMPv3 Check whether use of SNMPv1 is necessary. SNMPv1 is classified as non-secure. Use the option of preventing write access.
  • Page 20 Closed Closed ✓ ✓ ✓ Optional UDP/1813 SFTP Server TCP/22 Outgoing only Outgoing on‐ ✓ ✓ ✓ ✓ Siemens Re‐ TCP/443 Outgoing only Outgoing on‐ ✓ Optional ✓ mote Serv‐ ice (cRSP/ SRS) SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 21 Security recommendations 2.2 Available services Service Protocol/ Default port status Configurable Authenti‐ Encryp‐ Port number cation tion Local access External ac‐ Port Serv‐ cess SINEMA RC HTTPS/443 Outgoing only Outgoing on‐ ✓ ✓ ✓ ✓ and TCP/UDP depending on the server configuration SMTP Client TCP/25...
  • Page 22 Security recommendations 2.2 Available services The table includes the following columns: • Layer 2 service The Layer 2 services that the device supports. • Default status The default status of the service (open or closed). • Service configurable Indicates whether the service can be configured via WBM / CLI. Layer 2 service Default status Configurable...
  • Page 23: Description Of The Device

    Description of the device Product characteristics Interfaces Functionality SCALANCE M874-2 SCALANCE M876-3 SCALANCE M874-3 SCALANCE M876-4 Connectors for external antennas SMA antenna connector SMA antenna connectors Ethernet interface 2 x RJ45 10 / 100 Mbps 4 x RJ45 10 / 100 Mbps Digital input/output Using the device in a PROFINET environment Note...
  • Page 24: Device Views

    Description of the device 3.2 Device views Device views 3.2.1 SCALANCE M874 On the device front: ① Antenna connector A1, type SMA female ② Ethernet connectors (P1, P2) ③ SET button ④ Digital input (DI) ⑤ Digital output (DO) ⑥ Power supply connection ⑦...
  • Page 25: Scalance M876

    Description of the device 3.3 Scope of delivery 3.2.2 SCALANCE M876 On the device front: ① Antenna connector A2, type SMA female ② Antenna connector A1, type SMA female ③ Ethernet connectors (P1, P2, P3, P4) ④ SET button ⑤ Digital input (DI) ⑥...
  • Page 26: Accessories

    2. Check all the parts for transport damage. Accessories Technical data subject to change. You will find further information on the range of accessories in the Industry Mall (https:// mall.industry.siemens.com/mall/en/WW/Catalog/Products/10022025) Use the TIA Selection Tool (https://mall.industry.siemens.com/tst/) for configuring the device. SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 27: Installation

    Description of the device 3.4 Accessories 3.4.1 Installation Type Properties Article number 19" mounting frame SCALANCE M-800 19" mounting frame for in‐ 6GK5898-8MR00 stallation in 19" rack Desktop pedestal SCALANCE M-800 desktop pedestal for table 6GK5898-8MD00 mounting for SCALANCE M812 / M816 / M874- X / M876-X / S615 3.4.2 PLUG...
  • Page 28: Antennas

    Description of the device 3.4 Accessories Type Properties Article number SIMATIC NET N-Connect Flexible connecting cable, e.g. for connecting   Male/Male antennas, suitable for IWLAN and mobile wire‐ less, different lengths 1 meter 6XV1875-5AH10 2 meters 6XV1875-5AH20 5 meters 6XV1875-5AH50 5 meters 6XV1875-5AH50 10 meters 6XV1875-5AN10 Flexible connecting cable, e.g.
  • Page 29: Accessories

    Description of the device 3.4 Accessories Type Properties Article number ANT897-4MA Mobile wireless antenna with omnidirectional 6GK5897-4MA00-0AA3 characteristic for public and private LTE 4G/5G mobile wireless networks worldwide; 600 ... 5000 MHz; antenna gain: 1 ... 2 dBi, incl. SMA connector (male); IP65, -20 ... +65 °C, for direct mounting on SCALANCE devices with SMA con‐...
  • Page 30: Terminals

    Description of the device 3.5 Terminals Terminals Position The device has a 5-pin plug-in terminal block for the power supply and two 2-pin plug-in terminal blocks for the digital input and output. Connectors and terminal markings L1, M1, L2, M2 Input for the power supply Terminal block with five terminal con‐...
  • Page 31: Led Display

    Description of the device 3.6 LED display Terminals and wiring Connectors +DI, -DI /+D0, -DO L1, M1, L2, M2 28 AWG 16 AWG Wire end ferrule without plas‐ 0.2 mm 1.5 mm tic collar to DIN 46228/1 Wire end ferrule with plastic 0.2 mm 1.5 mm collar to DIN 46228/4...
  • Page 32 Description of the device 3.6 LED display Status Meaning No fault/error. The device is starting up or an error has occurred. Possible errors/faults: • Wrong PIN number • The inserted PLUG has an invalid or incompatible configuration. Flashing The bootloader waits in this state for a new firmware file that you can download using TFTP.
  • Page 33 Description of the device 3.6 LED display Status Meaning No VPN connection is established. All configured VPN connections are established. Flashing Only some of the configured VPN connections are established. P1/P2 Ethernet connection to local computer or LAN not established. Ethernet connection to local computer or LAN established. Device receiving/sending data.
  • Page 34: Scalance M876

    Description of the device 3.6 LED display 3.6.2 SCALANCE M876 SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 35 Description of the device 3.6 LED display Status Meaning No fault/error. The device is starting up or an error has occurred. Possible errors/faults: • Wrong PIN number • The inserted PLUG has an invalid or incompatible configuration. Flashing The bootloader waits in this state for a new firmware file that you can download using TFTP.
  • Page 36 Description of the device 3.6 LED display Status Meaning No VPN connection is established. All configured VPN connections are established. Flashing Only some of the configured VPN connections are established. Ethernet connection to local computer or LAN not established. Ethernet connection to local computer or LAN established. Device receiving/sending data.
  • Page 37: Set Button

    Description of the device 3.7 SET button SET button Position The SET button is on the front of the device beside the LED display. SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 38: Plug

    Description of the device 3.8 PLUG Function The SET button has the following functions: • Restarting the device To restart the device, press the SET button briefly. Note If you make changes to the configuration and restart immediately afterwards with the SET button, the changes may be lost.
  • Page 39 Description of the device 3.8 PLUG The following PLUG types are available: • C-PLUG: The removable data storage medium only saves the configuration data of the device. • KEY-PLUG: In addition to the configuration data, the removable data storage medium contains a license with which specific functions can be enabled, e.g. SINEMA RC. •...
  • Page 40 – The configuration data of the device is stored in a secured memory area of the PLUG. This secured memory area can only be accessed via the authentication of the Siemens device. – The device checks whether or not a PLUG is inserted at one second intervals. If the device detects that the PLUG has been removed, it restarts automatically.
  • Page 41: Installation And Removal

    Installation and removal Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. NOTICE Improper mounting Improper mounting may damage the device or impair its operation. • Before mounting the device, always ensure that there is no visible damage to the device. •...
  • Page 42 Installation and removal 4.1 Safety notices for installation Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1, Division 2 or Zone 2. WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
  • Page 43 Installation and removal 4.1 Safety notices for installation WARNING Wall mounting is only permitted if the requirements for the housing, the installation regulations, the clearance and separating regulations for the control cabinets or housings are adhered to. The control cabinet cover or housing must be secured so that it can only be opened with a tool.
  • Page 44: Securing The Housing

    Installation and removal 4.2 Securing the housing Securing the housing Types of installation For the device, you have the following options: • Wall mounting (no ceiling mounting) • Installation on a DIN rail • Installation on the S7-300 mounting rail • Installation on the S7-1500 mounting rail •...
  • Page 45: Wall Mounting

    Installation and removal 4.3 Wall mounting Wall mounting Note The wall mounting must be capable of supporting four times the weight of the device, but at least 50 N. For information on the weight, refer to the section "Technical specifications (Page 75)". Requirement There is a mini SIM card for the device.
  • Page 46: Installation On The Din Rail

    Installation and removal 4.4 Installation on the DIN rail 4. Connect the device to the local network, refer to the section "Ethernet port (Page 66)". 5. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-sectional area ≥...
  • Page 47: Installing On The S7-300 Standard Rail

    Installation and removal 4.5 Installing on the S7-300 standard rail Uninstalling 1. Disconnect all connected cables. 2. Using a screwdriver, pull down the catch on the rear of the device. 3. Pull lower part of the device away from the DIN rail. Installing on the S7-300 standard rail Requirement There is a mini SIM card for the device.
  • Page 48: Installing On The S7-1500 Standard Rail

    Installation and removal 4.6 Installing on the S7-1500 standard rail 7. Connect the device to the local network, refer to the section "Ethernet port (Page 66)". 8. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-sectional area ≥...
  • Page 49: Installation In A 19" Mounting Frame

    Installation and removal 4.7 Installation in a 19" mounting frame ③ 4. Swing the device down while pulling down the catch . After it is released, the spring catch locks in place. 5. Connect the power supply, refer to the section "Power supply (Page 59)". 6.
  • Page 50 Installation and removal 4.7 Installation in a 19" mounting frame Installation 1. Insert the SIM card, refer to the section "SIM card (Page 67)". 2. Push the devices into the mounting frame. 3. Press the devices with slight pressure onto the back wall until the spring catch locks in place. 4.
  • Page 51: Installation On A Desktop Pedestal

    Installation and removal 4.8 Installation on a desktop pedestal Installation on a desktop pedestal Requirement There is a mini SIM card for the device. Installation 1. Insert the SIM card, refer to the section "SIM card (Page 67)". ① 2. Place the third housing guide of the device on the top edge of the pedestal ②...
  • Page 52 Installation and removal 4.8 Installation on a desktop pedestal Uninstalling 1. Disconnect all connected cables. 2. Using a screwdriver, pull down the catch on the rear of the device. 3. Remove the device from the pedestal. SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 53: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. Note Strain relief for the Ethernet cables In order to avoid mechanical stress on the Ethernet cables and resulting interruption of the contact, fasten the cables at a short distance from the connector using a cable guide or busbar.
  • Page 54 Connecting up 5.1 Safety when connecting up Note Protective ground A PELV circuit contains a connection to protective ground. Without a connection to protective ground, or in case there is a fault in the connection to the protective ground, the voltage for the circuit is not stabilized.
  • Page 55 Connecting up 5.1 Safety when connecting up NOTICE Suitable fuse for the power supply cables (corresponds to "Limited Energy") The current on the terminal may not exceed 3 A. Use a fuse for the power supply that is suitable for protection of AC/DC power supply circuits * and protects against currents >...
  • Page 56 Connecting up 5.1 Safety when connecting up WARNING EXPLOSION HAZARD Do not press the SET button if there is a potentially explosive atmosphere. WARNING Unsuitable cables or connectors Risk of explosion in hazardous areas • Only use connectors that meet the requirements of the relevant type of protection. •...
  • Page 57 Connecting up 5.1 Safety when connecting up WARNING Insufficient isolation of intrinsically safe and non-intrinsically safe circuits Risk of explosion in hazardous areas • When connecting intrinsically safe and non-intrinsically safe circuits, ensure that the galvanic isolation is performed properly in compliance with local regulations (e.g. IEC 60079-14).
  • Page 58 Connecting up 5.1 Safety when connecting up WARNING Restricted area of application This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. Further notes WARNING Safety notice for connecting with a LAN ID (Local Area Network) A LAN or LAN segment with all the interconnected devices should be contained completely in a single low voltage power distribution in a building.
  • Page 59: Power Supply

    Connecting up 5.2 Power supply Power supply The power supply is connected using a 5-pin terminal block. The power supply is non-floating. Signal Description 24 VDC Ground Ground 24 VDC Functional ground, refer to the section "Grounding (Page 60)" You can find information on wiring in the section "Terminals". External power supply Refer to the section Connecting up (Page 53) and the installation instructions and instructions for use of the manufacturer of the power supply, the battery or the accumulator.
  • Page 60: Grounding

    Connecting up 5.3 Grounding Note The requirements of EN61000-4-5, "Surge Immunity Test" on power supply lines with 24 VDC are met only when a Blitzductor is used: 24 VDC: BVT AVD 24 type no. 918 422 Vendor: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D - 92306 Neumarkt, Germany Note External power supply for operation in China...
  • Page 61: Digital Input/Output

    Connecting up 5.4 Digital input/output With automation components, functional ground also ensures interference-free operation of a controller. Via the functional ground, interference currents coupled in via the connecting cables are discharged to ground. In terms of the large-area and low impedance implementation, a functional ground set up for this purpose generally also meets the requirements of protective earth.
  • Page 62 Connecting up 5.4 Digital input/output Digital input The 2-pin terminal block has the following assignment: Contact Assignment Input Ground If there is an adequate switching voltage at the digital input, the digital input is active and the "DI" LED is lit. The voltage applied to the "DI"...
  • Page 63: Antennas

    Connecting up 5.5 Antennas Digital output The 2-pin terminal block has the following assignment: Contact Assignment Switching signal Ground The output is a switch that switches the signal at +DO to ‑DO. Antennas Note Use the antennas from the accessories program for the M87x device. You will find more detailed information in "Accessories (Page 29)".
  • Page 64 Connecting up 5.5 Antennas The antenna socket for connecting the antenna is of the type SMA. The antenna used should have an impedance of about 50 ohms. CAUTION Minimum clearance to the device The device may only be operated when the distance between the device (or antenna) and user is at least 20 cm.
  • Page 65 Connecting up 5.5 Antennas Procedure 1. Insert the connector on the antenna cable into the SMA socket and tighten the sleeve nut of the plug on the socket (key size SW8, tightening torque 0.6 Nm). NOTICE The SMA socket may be damaged When securing an antenna to the device, only the screw cap of the antenna can be rotated.
  • Page 66: Ethernet Port

    Connecting up 5.6 Ethernet port If the "Q" LED is lit permanently, the signal quality is good. For more detailed information, refer to the section "LED display (Page 31)". Avoid large metal objects in the immediate vicinity. Position The SCALANCE M874 has an SMA antenna connector for a UMTS/GSM antenna and the SCALANCE M876 has two SMA antenna connectors for two LTE/UMTS/GSM antennas for diversification.
  • Page 67: Sim Card

    Connecting up 5.7 SIM card SIM card NOTICE Damage to the SIM card during replacement Before you insert or remove the SIM card, turn off the power supply of the SCALANCE M-800. Do not open the SIM card tray during operation. This can damage the SIM card and the device. The tray for the 2FF mini SIM card is located on the back of the device.
  • Page 68: Replacing The Plug

    Connecting up 5.8 Replacing the PLUG Replacing the PLUG NOTICE Do not remove or insert a C-PLUG / KEY-PLUG during operation! A PLUG may only be removed or inserted when the device is turned off. The device checks whether or not a PLUG is present at one second intervals. If it is detected that the PLUG was removed, there is a restart.
  • Page 69 Connecting up 5.8 Replacing the PLUG Removing the PLUG 1. Turn off the power to the device. 2. Insert a screwdriver between the front edge of the PLUG and the slot and release the PLUG. 3. Remove the PLUG. SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 70 Connecting up 5.8 Replacing the PLUG SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 71: Maintenance And Cleaning

    Maintenance and cleaning WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
  • Page 72 Maintenance and cleaning SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 73: Troubleshooting

    Troubleshooting Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Procedure with Microsoft Windows You can download new firmware to the device using TFTP. To do this, the device does not need to be reachable either using Web Based Management (WBM) or using the Command Line Interface (CLI).
  • Page 74: Restoring The Factory Settings

    Troubleshooting 7.2 Restoring the factory settings Restoring the factory settings NOTICE If you reset, all the settings you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in a configured network with further consequences.
  • Page 75: Technical Specifications

    Technical specifications SCALANCE M874-2   M874-2 Article number 6GK5 874-2AA00-2AA2 Ethernet interface Connection to Industrial Quantity Ethernet   Design RJ-45 jack   Characteristics: • 10/100BASE-T • Ethernet IEEE 802.3 • 10/100 Mbps Wireless interface Antenna connector Quantity   Design SMA socket (straight)  ...
  • Page 76 Technical specifications 8.1 SCALANCE M874-2   M874-2 Digital input Quantity Design Terminal block, 2-pin Properties Rated voltage 24 VDC Safety Extra Low Voltage (SELV) For state "1": 10 to 30 VDC For state "0": -30 to 3 VDC Maximum input current 8 mA Cables should be routed in pairs Maximum cable length <...
  • Page 77 – To establish a VPN (Virtual Private Net‐ work), the following functions are available – Up to 20 connections – IPsec VPN, OpenVPN (as client) • SINEMA RC client • Proxy server • Siemens Remote Service (SRS) SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 78: Scalance M874-3

    Technical specifications 8.2 SCALANCE M874-3   M874-2 Monitoring / diagnostics / maintenance • LEDs Display of operating statuses via the LED dis‐ play. You will find additional information on this in the operating instructions of the device. • Logging Events can be logged for monitoring. •...
  • Page 79 Technical specifications 8.2 SCALANCE M874-3   M874-3 Antenna connector Quantity   Design SMA socket (straight)   Impedance 50 Ω nominal   Antenna cable Cable length < 30 m Frequency bands UMTS 800 MHz, 850 MHz, 900 MHz, 1800 MHz, 1900 MHz, 2100 MHz 850 MHz, 900 MHz, 1800 MHz, 1900 MHz UMTS with HSPA+ Transmission speed...
  • Page 80 Technical specifications 8.2 SCALANCE M874-3   M874-3 Digital output Quantity Design Terminal block, 2-pin Properties Rated voltage 24 VDC Safety Extra Low Voltage (SELV) Relay, internally not current limited Maximum current carrying capacity 1 A Cables should be routed in pairs Maximum cable length <...
  • Page 81 – To establish a VPN (Virtual Private Net‐ work), the following functions are available – Up to 20 connections – IPsec VPN, OpenVPN (as client) • SINEMA RC client • Proxy server • Siemens Remote Service (SRS) SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 82: Scalance M876-3

    Technical specifications 8.3 SCALANCE M876-3   M874-3 Monitoring / diagnostics / maintenance • LEDs Display of operating statuses via the LED dis‐ play. You will find additional information on this in the operating instructions of the device. • Logging Events can be logged for monitoring. •...
  • Page 83 Technical specifications 8.3 SCALANCE M876-3   M876-3 Antenna connector Quantity   A1: Main antenna   A2: UMTS: RX diversity Design SMA socket (straight) Impedance 50 Ω nominal Antenna cable Cable length < 30 m Frequency bands 850 MHz, 900 MHz, 1800 MHz, 1900 MHz UMTS with HSPA+ 800 MHz, 850 MHz, 900 MHz, 1800 MHz, 1900 MHz, 2100 MHz...
  • Page 84 Technical specifications 8.3 SCALANCE M876-3   M876-3 Digital input Quantity Design Terminal block, 2-pin Properties Rated voltage 24 VDC Safety Extra Low Voltage (SELV) For state "1": 10 to 30 VDC For state "0": -30 to 3 VDC Maximum input current 8 mA Cables should be routed in pairs Maximum cable length <...
  • Page 85 – To establish a VPN (Virtual Private Net‐ work), the following functions are available – Up to 20 connections – IPsec VPN, OpenVPN (as client) • SINEMA RC client • Proxy server • Siemens Remote Service (SRS) SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 86: Scalance M876-4 (Eu)

    Technical specifications 8.4 SCALANCE M876-4 (EU)   M876-3 Monitoring / diagnostics / maintenance • LEDs Display of operating statuses via the LED dis‐ play. You will find additional information on this in the operating instructions of the device. • Logging Events can be logged for monitoring. •...
  • Page 87 Technical specifications 8.4 SCALANCE M876-4 (EU)   M876-4 Antenna connector Quantity   A1: Main antenna   A2: UMTS: RX diversity       LTE: RX MIMO Design SMA socket (straight) Impedance 50 Ω nominal Antenna cable Cable length < 30 m Frequency bands 2100 MHz, 1800 MHz, 2600 MHz, 900 MHz, 800 MHz ...
  • Page 88 Technical specifications 8.4 SCALANCE M876-4 (EU)   M876-4 Digital input Quantity Design Terminal block, 2-pin Properties Rated voltage 24 VDC Safety Extra Low Voltage (SELV) For state "1": 10 to 30 VDC For state "0": -30 to 3 VDC Maximum input current 8 mA Cables should be routed in pairs Maximum cable length <...
  • Page 89 – To establish a VPN (Virtual Private Net‐ work), the following functions are available – Up to 20 connections – IPsec VPN, OpenVPN (as client) • SINEMA RC client • Proxy server • Siemens Remote Service (SRS) SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 90: Scalance M876-4 (Nam)

    Technical specifications 8.5 SCALANCE M876-4 (NAM)   M876-4 Monitoring / diagnostics / maintenance • LEDs Display of operating statuses via the LED dis‐ play. You will find additional information on this in the operating instructions of the device. • Logging Events can be logged for monitoring. •...
  • Page 91 Technical specifications 8.5 SCALANCE M876-4 (NAM)   M876-4 (NAM) Antenna connector Quantity   A1: Main antenna   A2: UMTS: RX diversity       LTE: RX MIMO Design SMA socket (straight) Impedance 50 Ω nominal Antenna cable Cable length < 30 m Frequency bands 700 MHz, 850 MHz, AWS-1 (1700/2100) MHz, 1900 MHz UMTS with HSPA+ 850 MHz, AWS-1 (1700/2100) MHz, 1900 MHz...
  • Page 92 Technical specifications 8.5 SCALANCE M876-4 (NAM)   M876-4 (NAM) Digital input Quantity Design Terminal block, 2-pin Properties Rated voltage 24 VDC Safety Extra Low Voltage (SELV) For state "1": 10 to 30 VDC For state "0": -30 to 3 VDC Maximum input current 8 mA Cables should be routed in pairs Maximum cable length <...
  • Page 93 – To establish a VPN (Virtual Private Net‐ work), the following functions are available – Up to 20 connections – IPsec VPN, OpenVPN (as client) • SINEMA RC client • Proxy server • Siemens Remote Service (SRS) SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 94: Scalance M876-4

    Technical specifications 8.6 SCALANCE M876-4   M876-4 (NAM) Monitoring / diagnostics / maintenance • LEDs Display of operating statuses via the LED dis‐ play. You will find additional information on this in the operating instructions of the device. • Logging Events can be logged for monitoring. •...
  • Page 95 Technical specifications 8.6 SCALANCE M876-4   M876-4 Antenna connector Quantity   A1: Main antenna   A2: UMTS: RX diversity       LTE: RX MIMO Design SMA socket (straight) Impedance 50 Ω nominal Antenna cable Cable length < 30 m Frequency bands LTE bands B1, B2, B3, B4, B5, B7, B8, B12, B13, B18, B19, B20, B26, B28, B66 LTE TDD: B38, B40, B41...
  • Page 96 Technical specifications 8.6 SCALANCE M876-4   M876-4 Digital input Quantity Design Terminal block, 2-pin Properties Rated voltage 24 VDC Safety Extra Low Voltage (SELV) For state "1": 10 to 30 VDC For state "0": -30 to 3 VDC Maximum input current 8 mA Cables should be routed in pairs Maximum cable length <...
  • Page 97 – To establish a VPN (Virtual Private Net‐ work), the following functions are available – Up to 20 connections – IPsec VPN, OpenVPN (as client) • SINEMA RC client • Proxy server • Siemens Remote Service (SRS) SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 98: Antenna Gain

    Technical specifications 8.7 Antenna gain   M876-4 Monitoring / diagnostics / maintenance • LEDs Display of operating statuses via the LED dis‐ play. You will find additional information on this in the operating instructions of the device. • Logging Events can be logged for monitoring. •...
  • Page 99 Technical specifications 8.7 Antenna gain Antenna gain for M876-4 Note Depending on the selected wireless standard and the wireless frequency used, antennas with different antenna gains can be used. If you change the frequency band during operation, it is possible that the maximum permitted antenna again also changes. Check whether the antenna you are using is approved for the changed frequency range.
  • Page 100 Technical specifications 8.7 Antenna gain IC (Canada) Frequency band Maximum antenna gain in dBi 850 MHz 850 MHz = band 5 0.16 700 MHz = band 13 0.16 700 MHz = band 17 0.16 850 MHz = GSM 850 0.16 UMTS with HSPA+ 850 MHz = band V 0.16 1700 MHz...
  • Page 101: Dimension Drawings

    Dimension drawings Note CAx data You can find the CAx data on the Internet at (https://www.automation.siemens.com/bilddb/ index.aspx?lang=en) 1. Click on the "CAx data" link in the "Direct Links" area. The Industry Image Database page is loaded. 2. Enter the name or article number of the product in the search filter.
  • Page 102: Scalance M874

    Dimension drawings 9.1  SCALANCE M874 SCALANCE M874 Dimensions are specified in mm. 126,8 134,7 Figure 9-1 Side view M874-2 and M874-3 SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 103 Dimension drawings 9.1  SCALANCE M874 34,8 Figure 9-2 Front view M874-2 and M874-3 SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 104: Scalance M876

    Dimension drawings 9.2 SCALANCE M876 SCALANCE M876 Dimensions are specified in mm. Figure 9-3 M876-3 and M876-4 side view SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 105 Dimension drawings 9.2 SCALANCE M876 34,8 Figure 9-4 M876-3 and M876-4 front view SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 106: 19" Installation Frame

    Dimension drawings 9.3 19" installation frame 19" installation frame Dimensions are specified in mm. Figure 9-5 Front view SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 107: Approvals

    Approvals for shipbuilding are not printed on the device type plate. National approvals You can find an overview of the country-specific wireless approvals of SIMATIC NET devices on the Internet pages of Siemens Industry Online Support. You can find the link to the document on the following page ik-Info (https://www.siemens.com/mobilenetwork-approvals)
  • Page 108: Ec Declaration Of Conformity

    Siemens Aktiengesellschaft   Digital Industries Process Automation DE-76187 Karlsruhe Germany You can find the current EU declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15987/cert). SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 109: Atex

    Approvals 10.1 EC declaration of conformity The products described in this document meet the requirements of the following EC directives: • ATEX directive 2014/34/EU Directive of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres;...
  • Page 110: Red

    Approvals 10.1 EC declaration of conformity Applied standard: EN IEC 63000 Technical documentation for the assessment of electrical and electronic products with respect to restriction of hazardous substances 10.1.3 10.1.3.1 Protection of health and safety The products described in this document meet the requirements of the applied standards: Article 3 (1) a) protection of health and safety EN 62368-1+A11 Audio/video, information and communication technology equipment - Part 1: Safety...
  • Page 111: Efficient Use Of The Radio Spectrum

    Approvals 10.1 EC declaration of conformity EN 50121-3-2 Railway applications - Electromagnetic compatibility - part 3-2: Rolling stock - Devices EN 50121-4 Railway applications - Electromagnetic compatibility - part 4: Emission and immunity of the signaling and telecommunications apparatus EN 55032 + A11 Electromagnetic compatibility of multimedia equipment –...
  • Page 112: Other Technical Standards

    Importer UK:   Siemens plc, Manchester M20 2UR United Kingdom You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15987/cert). SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...
  • Page 113: The Equipment And Protective Systems Intended For Use In Potentially Explosive Atmospheres Regulations 2016

    Approvals 10.2 UK Declaration of Conformity The SIMATIC NET products described in this document meet the requirements of the following directives: • UK Regulation SI 2016/1107 The Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres Regulations 2016, and related amendments •...
  • Page 114: Radio Equipment Regulations 2017

    Approvals 10.2 UK Declaration of Conformity 10.2.3 Radio Equipment Regulations 2017 10.2.3.1 Protection of health and safety The products described in this document meet the requirements of the applied standards: Article 3 (1) a) protection of health and safety EN 62368-1+A11 Audio/video, information and communication technology equipment - Part 1: Safety requirements EN 62311...
  • Page 115: Efficient Use Of The Radio Spectrum

    Approvals 10.2 UK Declaration of Conformity EN 55035 + A11 Electromagnetic compatibility of multimedia equipment - Immunity requirements EN 61000‑6‑1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000‑6‑2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments EN 61000‑6‑3 + A1 + AC Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard...
  • Page 116: Products

    Process Automation DE-76187 Karlsruhe Germany You can find the current Supplier's declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15987/cert) As required by the following Notices: • Radiocommunications (Compliance Labelling - Devices) Notice 2014 made under section 182 of the Radiocommunications Act 1992;...
  • Page 117: General Approvals

    "SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013).
  • Page 118 Approvals 10.4 General approvals The product meets the requirements of the standards: • Factory Mutual Approval Standard Class Number 3611 / 3600 / 3810 / ANSI ISA-61010-1 • FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 cULus Approval for Information Technology Equipment cULus Listed I.
  • Page 119 • Telecommunications (Labelling Notice for Customer Equipment and Customer Cabling)Instrument 2015 made under section 407 of the Telecommunications Act 1997 You can find the current declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/ 15914/cert)
  • Page 120 Approvals 10.4 General approvals Conformity with FCC The FCC approval applies to the following SCALANCE M device: FCC ID SCALANCE M874-3 QIPPHS8-P SCALANCE M876-3 QIPPHX8 SCALANCE M876-4 (NAM) QIPPLS8-X FCC Part 15 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 121 Approvals 10.4 General approvals This device contains GSM, GPRS Class 12, EGPRS Class 10, and UMTS functions in the 900 and 1800 MHz band that must not be used in territories of the USA. This device can be used for mobile and fixed applications. Internal / external antennas used with this device must be at a distance of at least 20 cm from all persons and must not be located so that they operate in combination with any other antenna or transmitter.
  • Page 122 Approvals 10.4 General approvals l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. See also Antenna gain (Page 98) Marking for the customs union EAC (Eurasian Conformity) Eurasian Economic Union of Russia, Belarus, Armenia, Kazakhstan and Kyrgyzstan Declaration of conformity according to the technical regulations of the customs union (TR ZU)
  • Page 123: Index

    Index External power supply China, 60 Accessories, 26 Antennas, 66 Approvals, 112, 116 Factory default, 38 Article numbers, 3 Factory setting, 74 Button, 37 Glossary, 7 Grounding, 60 CAx data, 101 CE conformity, 112 Installation Configuration manuals, 4, 74 19" mounting frame, 50 Connecting DIN rail, 46 Antennas, 66 Pedestal, 51 Digital input, 62 S7-1500 mounting rail, 48 Digital output, 63 S7-300 mounting rail, 47 Power supply, 30, 59 Wall, 45...
  • Page 124 Index Safety notices for installation, 41 general, 13 Use in hazardous areas, 13, 41, 53, 54 when connecting up, 53, 54 Scope of delivery, 25 Scope of validity, 3 SET button, 37, 73 Signal quality, 65 SIM card, 67 SIMATIC NET glossary, 7 System manual, 107 Terminals, 30 UK conformity, 116 Wall mounting, 45 Wiring, 31 SCALANCE M874, M876 Operating Instructions, 02/2023, C79000-G8976-C331-12...