7�6 Description of the electrical interfaces
7�6�1 General information
▶ For electric installation of the interfaces, proceed according to applicable
▶ You must ensure that the power supply is disconnected and also safeguarded
▶ Unintended activation should be prevented by means of a warning sign
For operation of the hydraulic power unit, at least the following electrical
connections are required:
• 12X1: Feed-in/voltage supply
• 15X1: 24 V interface
7�6�2 All configurations
Port 12X1: Feed-in/
The power supply to the CytroPac is provided via port 12X1.
voltage supply
▶ Assign the mating connector to the power supply as shown in Fig. 16.
Fig� 16: Assignment of port 12X1: Feed-in/voltage supply
regulations for electrical engineering.
against being switched on unintentionally.
indicating that work is carried out at the electrical system.
The power supply including fuse and mains contactor is to be implemented by
the customer.
To ensure a smooth connection to the power supply, it is imperative to use one
of the mating connectors offered by Bosch Rexroth without or with cables.
For a complete list of accessories, see data sheet 51055, see chapter 1.2
"Required and amending documentation".
+EXT
Assembly | CytroPac
-POWER
L1
L2
L3
PE
-12X1
1
2
3
PE