Premium" And "Premium M12" Configurations - Bosch Rexroth CytroPac Operating Instructions Manual

Hydraulic power unit
Hide thumbs Also See for Rexroth CytroPac:
Table of Contents

Advertisement

To connect the power supply, proceed as follows:
▶ Connect the filling level and temperature sensors, see Fig. 24 item, 1 and the
filter contamination sensors, see Fig. 24 item 2 and 3, (customer side).
▶ Connect the connector plug for the 24 V interface to the higher-level machine
control via port 15X1, see Fig. 24, item 9.
▶ Connect the connector plug for the feed-in / power supply to connection 12X1,
see Fig. 24, item 5.
7�7�2 "Premium" and "Premium M12" configurations
All ports are included in the "Premium" and "Premium M12" configurations.
Fig� 25: "Premium" (left) / "Premium M12" (right) configuration electrical connections
1 Filling level and temperature
sensor
1)
2 Filter contamination sensor 100 %
3 Filter contamination sensor 75 %
4 16X1: (M12 x 1) sensor evaluation,
wired at the plant
5 12X1: Feed-in/voltage supply
1)
The sensors are factory-wired and connected via a set of cables to the port 16X1.
2)
Optionally available
Assembly | CytroPac
6 21X1: Multi-Ethernet interface
7 21X2: Multi-Ethernet interface
8 22X1: STO interface
1)
9 15X1: 24 V interface
1)
(M12 x 1, 8-pole)
10 14X1: Mini USB service interface
RE 51055-B, Edition 07.2022, Bosch Rexroth AG