CytroPac | Assembly
Pressure line P
Return line T
Back-pressure protected
oil tank connections T
Bosch Rexroth AG, Edition 07.2022, RE 51055-B
7�3�1 Connecting the hydraulic supply with the standard version
Fig� 10: Connection lines on the standard version
1 Oil tank connection T: G1/2
2 Oil tank connections T: 2 x G1
3 Oil tank connection T: G1 (option A1)
4 Pressure port P: G1/2
▶ Close the pressure line with a G1/2 fitting via pressure port P: G1/2,
see Fig. 10, item 4.
▶ Install a pressure relief valve in the pressure line.
The pressure relief valve must be installed directly at the pressure output.
No valves or similar components may be installed between the pressure output
and the pressure relief valve.
For further information, refer to data sheet 51055, see chapter 1.2
"Required and amending documentation".
▶ Set the pressure relief valve to 10 % over the operating pressure, however,
to a maximum of 260 bar.
▶ Connect the return line via the return flow filter to the oil tank connection T:
G1/2, see Fig. 10, item 1.
▶ Close unused ports with plug screws.
▶ Optionally, you can use the non-return oil tank connections T: G1, see Fig. 10,
item 2 and item 3, e.g. for a rotary transmission leadthrough.
▶ Close unused ports with plug screws.