Screen
en
Desktop software: SFE tool as a file for download
Action steps
The SFE configuration can be exported without
calibration data (checkbox deactivated at Export
Calibration Config) or with calibration data
(checkbox activated at Export Calibration
Config).
• Exporting without calibration data: Only
fundamental user settings are exported
(baud rate, LED quality threshold, motor lock
timeout, motor velocity, temperature
compensation, lock mode).
• Exporting with calibration data: All
configuration data is exported, including the
motor and calibration configuration
performed at the factory.
Note
An export file with calibration data can
only be imported in calibration mode. As
calibration mode is only available for
calibration at the factory and service
tasks, only the user settings can be
imported from an export file with
calibration data.
 Click Export.
 The export is started.