12
Inactive protective measures
The transmission and processing of incorrect sensor data may lead to contact and
unexpected system behavior.
 When using the SFE, limit the machine movement by using suitable protective
measures.
 The SFE may only be used on systems and equipment with the protective
measures intended for the system.
 Only operate the SFE if the protective measures are enabled.
 Only move the system by teaching with the SFE if the safety area is active.
 If the protective measures are disabled, only operate the SFE in the control
state: "manual with reduced travel speed".
TPE bellows
If the bellows are exposed to oil and grease for a longer period of time, this may
lead to damage. Processes in which an absence of PWIS must be guaranteed may
be influenced by this.
 Avoid wetting and residues, and remove these promptly.
 Avoid mechanical damage which may cause tears/holes in the bellows.
 Do not expose the SFE to applications where PWIS conformity is required.
Warm-up behavior
Temperature-related behavior can negatively affect the sensors for environment or
application-specific influences during operation.
 By way of regular plausibility checks, ensure that the sensors are working
correctly.
 Compensate for possible changes to the sensor setting by regularly locking and
unlocking.