(4) Errors occurring at current value changes and speed changes (300 to 399)
The errors shown in this section are those that occur on execution of current
value changes and speed changes.
Error codes, causes, processing, and corrective actions are shown in table 2.8.
Table 2.8 List of Errors that Occur at Current Value/Speed Changes
Control Mode
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
search engine
Error Cause
• An attempt was made to change the current
value data of an axis in motion.
• An attempt was made to change the current
value data of an axis that had not been
started up.
• An attempt was made to change the current
value data of an axis whose status was
"servo OFF".
• An attempt was made to change the speed
of an axis executing a zeroing.
• An attempt was made to change the speed
of an axis executing circular interpolation.
• An attempt was made to change the speed
of an axis after automatic deceleration had
started in positioning.
• An attempt was made to change the speed
of an axis during deceleration initiated by
turning OFF the JOG operation start signal
(M1802+20n, M1803+20n).
• The speed to be changed to in a speed
change was set outside the range of 0 to the
speed limit value.
• A current value change command outside
×
-5
the range of 0 to 35999999 (
10
degrees)
has been issued for an axis whose control
units are degrees.
• A speed change was attempted during high-
speed oscillation.
• A speed change to "0" request was issued
during high-speed oscillation.
• A value outside the range 1 to 500% was
set in the torque limit value change request
(CHGT).
• A torque limit change request (CHGT) was
made for an axis not started yet.
APP − 14
Error
Corrective Action
Processing
• Use the following states of the following
devices as interlocks to ensure that the
present value of an axis in motion cannot
The current
be changed.
value data is
(1) OFF state of the start accept flag (M2001
not changed.
to M2004/M2001 to M2008) for the
relevant axis.
(2) ON state of the servo READY flag
M1615+20n.
• The speed of an axis executing zeroing
cannot be changed.
• The speed of an axis executing circular
interpolation cannot be changed.
• The speed of an axis cannot be changed
The speed is
after automatic deceleration has started.
not changed.
• Do not attempt a speed change during
deceleration initiated by turning OFF the
JOG operation start signal (M1802+20n,
M1803+20n).
• Set the speed within the range from 0 to
The speed is
kept at the
the speed limit value.
speed limit
value.
• Make a setting in the range of 0 to
The present
×
−5
35999999 (
10
degrees).
value data is
not changed.
• Do not perform speed changes during
The speed is
high-speed oscillation.
not changed.
• Make a change request within the range 1
to 500% .
The torque
limit value is
• Make a change request for a started axis.
not changed.