7. POSITIONING CONTROL
[Cautions]
[Program Example]
Downloaded from
ManualsNet.com
(1) The number of controllable axes is limited to one.
(2) Only the absolute data method (ABS ) is used for positioning control to the
pass points.
(3) The speed can be changed after control is started.
The changed speed remains valid until the stop command is input.
(4) Set the positioning address in the servo program using indirect designation with
the word devices D and W.
(5) Use only even-numbered devices for indirect designation of positioning ad-
dresses in a servo program.
If odd-numbered devices are used, when an attempt is made to start the con-
trol error 141 occurs and control does not start.
(6) Positioning speeds can be set in the servo program using indirect designation
with the word devices D and W.
However, this set speed is valid only at the start of position follow-up control (on
execution of SVST, DSFRP instructions) and the speed does not change if the
indirect designations are changed while control is in progress.
(1) System configuration
Position follow-up control of Axis 3.
A172SHCPUN
A172B
MR-[]-B
Axis 1
M
(2) Positioning conditions
(a) The position follow-up conditions are shown below.
Servo program number
Controlled axis
Positioning address
Positioning speed
(b) Position follow-up control start command .... leading edge of X000
(OFF → ON)
search engine
A172S
A1S
ENC
X10
Positioning start command
MR-[]-B
MR-[]-B
MR-[]-B
Axis 2
Axis 3
Axis
4
M
M
M
Item
Setting
100
Axis 3
D50
20000