Auxiliary And Applied Functions; Limit Switch Output Function; Limit Switch Output Function; Limit Switch Output Data - Mitsubishi Electric SV13/22 Programming Manual

Table of Contents

Advertisement

8. AUXILIARY AND APPLIED FUNCTIONS

8.1

Limit Switch Output Function

8.1.1

Limit switch output data

8.1.2

Limit switch output function

[Control Details]
Downloaded from
ManualsNet.com
The limit switch output function allows the A1SY42 output module or AY42 output
module to output ON/OFF signals corresponding to the positioning address set for
each axis.
Item
• −2147483648 to 2147483647
(× 10
ON/OFF point
• 0 to 35999999
setting
( 10
(1) The limit switch function outputs the ON/OFF pattern from the A1SY42/ AY42
at the set addresses.
Before running the limit switch output function, the ON/OFF point addresses
and the ON/OFF pattern must be set from a peripheral device.
(Settings cannot be made by the sequence program.)
The number of limit switch outputs per axis and the ON/OFF points are as
follows:
(a) Number of limit switch output points .............8 points/axis,
(b) ON/OFF points...............................................10 points/axis
MIN
1
ON
Point 1
OFF
Point 2
OFF
Point 3
ON
OFF
Point 4
8 points
/axis
OFF
Point 5
ON
Point 6
ON
OFF
Point 7
OFF
Point 8
search engine
Settings
− 1
− 5
µ m,× 10
inch, PLS)
− 5
degree)
ON/OFF switching points. 10 points/axis.
(Common for Point 1 through Point 8.)
2
3
4
5
6
OFF
ON
ON
ON
ON
OFF
ON
8 − 2
Initial
Value
Units
− 1
× 10
µ m
• Up to 10 points can
− 5
× 10
inch
0
be set for each
− 5
10
degree
axis.
PLS
total 64 points
Set an address in the stroke limit
range for each point.
MAX
7
8
9
10
Comments

Advertisement

Table of Contents
loading

This manual is also suitable for:

A172shcpunA171shcpun

Table of Contents