3.
Verify the ac power supply voltage (indicated on the label inside the H201Ci-C, near
the power supply terminal block) corresponds to the power source voltage and the
value on the Test Certificate and Data Sheet (for an example, see Figure 6-1 on
page 6-4). There are two possibilities:
• 115 V, corresponding to a 90–132 Vac range from 47 to 63 Hz
• 230 V, corresponding to a 180–264 Vac range from 47 to 63 Hz
4.
Ensure the H201Ci-C's serial number (indicated on the right internal side of the
enclosure wall or on the back of the door) corresponds to those indicated on the Test
Certificate and Data Sheet and on the shipping box.
5.
Report any discrepancy to the company supervisor and the General Electric Canada
Customer Service (the coordinates can be found at the bottom of page ii).
Note: Never return equipment without first contacting the General Electric Canada
Customer Service.
7.1.3

Storage

If the Hydran 201Ci-C is not installed immediately, it is strongly recommended to store it
in its original shipping box in a safe place.
Storage should be at a temperature between 5 and 45 °C (41 and 113 °F) and a non-
condensing, relative humidity between 5 and 95 %; if these limits are to be exceeded, please
contact the General Electric Canada Customer Service (the coordinates can be found at the
bottom of page ii). These restrictions do not apply to transportation.
7.2

VERIFICATION OF OPERATION PRIOR TO INSTALLATION

It is strongly recommended to verify the operation of the Hydran 201Ci-C Controller(s)
before installation in the field. The verification confirms that no damage occurred during
shipping and allows the user to become familiar with the H201Ci-C.
7.2.1

Preparation

To verify its operation, the Hydran 201Ci-C must first be connected to at least one
functional Hydran 201Ti via a supervisory link cable. One end of this cable is already
connected to the H201Ti. For details on commissioning the H201Ti('s), see Chapter 6.