ACTION
1) Press Transfer button and enter 816.
Display shows:
2) Press Volume button to make selection and
press Right Soft button to make change and
to move cursor.
3) Dial 3,4 or 5.(e.g., 4 part conference bridge)
OR
Press Volume button to make selection and
press Right Soft button to move cursor.
4) Dial 0 to 4.(e.g., 2 analog trunk member)
OR
Press Volume button to make selection and
press Right Soft button to move cursor.
5) Press Volume button to select CNF gain and
press Right Soft button to move cursor.
6) Press Volume button to select SW gain and
press Right Soft button to save and move cursor.
7) Press Transfer button and enter to exit.
OR
Press Speaker button to advance next MMC.
RELATED ITEMS
NONE
© SAMSUNG Electronics Co., Ltd.
OfficeServ 500 Programming Guide
DISPLAY
CONFERENCE GAIN
USE DEFAULT :YES
CONFERENCE GAIN
USE DEFAULT :NO
MEMBER:4 A-TRK:0
CNF:-6.0 SW:+0.0
MEMBER:4 A-TRK:2
CNF:-6.0 SW:2.5
MEMBER:4 A-TRK:2
CNF:-6.0 SW:2.5
MEMBER:4 A-TRK:2
CNF:-6.0 SW:-6.0