[702] TOLL DENY TABLE

Provides a way to make toll restriction(call barring) very easy and flexible. There are 500
entries allowed in the deny and each entry index can be assigned to a class of service. Each
index can have up to 12 digits. With the use of wild cards(MMC 704 Assign Wild Character),
more flexibility can be built into toll restriction. Wild cards can be used repeatedly in the
dial string, limited only to what is allowed or denied in MMC 704.
There are six toll levels, B to G, that are programmable. Toll level A is set as unrestricted by
default and toll level H is set as in-house only by default.
CONDITIONS
NONE
DEFAULT DATA
ALL ENTRIES ARE SET TO 0
PROGRAM BUTTONS
A
Used to wild card X entered
B
Used to wild card Y entered
C
Used to wild card Z entered
ACTION
1) Press Transfer button and enter 702.
Display shows:
2) Dial index number.(e.g., 005)
OR
Press Volume button to select index and press
Right Soft button to move cursor.
3) Enter toll pattern via dial pad.(e.g., 212)
OR
Enter wild card(e.g., 21X) from above list and press
Right Soft button to move cursor to COS options.
© SAMSUNG Electronics Co., Ltd.
OfficeServ 500 Programming Guide
DISPLAY
DENY(001):BCDEFG
:000000
DENY(005):BCDEFG
:000000
DENY(005):BCDEFG
212
:000000
DENY(005):BCDEFG
21X
:000000
2-219