Alarm, error, and system messages
10.5 Error messages
10.5.3

Error list AddOn

10.5.3.1

Overview

The errors from the sway control system are categorized as follows:
General and severe errors
Errors in the limit or prelimit switch area
Errors in semi-automatic mode
Other errors 1
Other errors 2
TLS errors
10.5.3.2

Brief description

The assignment of the error bits to the error messages in the output data are as follows:
Table 10-1
General and severe errors (error double word 1)
Error
Bit No.
Brief description
E0
-
Cycle time too long
E1
13
Error in the DCC chart
E2
14
Copy protection damaged
E3
3
License error
E4
12
Camera measuring system faulted
E5
1
Invalid mode, trolley
E6
1
Invalid mode, hoist
E7
9
Invalid mode at the limit switch, trolley
E8
9
Invalid mode at the limit switch, hoist
E9
-
Step change in hoisting height
E10
0
Invalid parameter file
E11
-
Invalid parameter value
E12
-
Language file error
E13-E19
-
Reserved
-
20
Actual position over- or undershoots the limits of the set value range.
Note:
This error is not displayed in the SIMOCRANE CeCOMM diagnostic program and must be handled
by the higher-level control system.
Table 10-2
Errors in the limit or prelimit switch area
Error
Bit No.
Brief description
E20
-
Forward prelimit switch switches incorrectly, trolley
E21
-
Upper prelimit switch switches incorrectly, hoist
374
E0
E20 to
E30 to
E50 to
E60 to
E69 to
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
to
E19
E29
E49
E59
E68
E84