Display:
● Internal targets
The "target position" has the following suffix: xxxxx (int.)
● External targets
The "target position" has no suffix: xxxxx
The screenshot below demonstrates the differences in the display of external and internal
targets.
Figure 9-16
9.4.3.2

Changing the coordinate system

If automatic positioning is to be commissioned and the coordinate system of the trolley also
needs to be changed, the position values must be converted.
In the "Calculations" window of the SIMOCRANE CeCOMM diagnostic program, two position
values of the previous coordinate system must be entered in the "Measured value" column, and
the two associated position values of the new coordinate system in the "Position value" column.
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Displaying external and internal targets in the "PLC Interface 1 [2]" screen
Commissioning AddOn Software
9.4 Sway control commissioning
343