Figure 8-15
Status display number 4 helps to track the system status in SAM mode.
8.5.2

TLS monitors

Naming system for TLS
Signals with the ending "_ABCD" and with the ending "_TLSh" are named as follows:
● Ending "_ABCD": Representation in relation to the cylinders.
● Ending "_TLSh": Representation in relation to the orientation of the spreader with the
components trim, list, skew, and vertical translation.
That is, each of the signals comprises four components. For naming individual components, the
endings "_A," "_B," "_C," and "_D," or "T," "_L," "_S," and "_h" are valid.
The following applies, as exemplified for the actual position:
s_act_T = 0.25 · (s_act_A + s_act_B – s_act_C – s_act_D)
s_act_L = 0.25 · (s_act_A – s_act_B – s_act_C + s_act_D)
s_act_S = 0.25 · (–s_act_A + s_act_B – s_act_C + s_act_D)
s_act_h = 0.25 · (s_act_A + s_act_B + s_act_C + s_act_D)
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
SIMOCRANE CeCOMM commissioning and diagnostic program
CeCOMM monitor 4
8.5 Monitor (tab)
277