Options
9.13 K48, Sensor Module Cabinet-Mounted SMC20
NOTICE
Damage to the motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
Note
P sense and M sense
The cables for P sense or M sense with P encoder or M encoder must be jumpered at the
encoder end. The supply voltage of the encoder is detected by the SMC20 and automatically
adjusted to 5 V to compensate any power loss.
Note
Maximum signal cable length
The maximum signal cable length is 100 m.