Siemens SINAMICS G130 Manual page 22

Safety integrated
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Typicals and regulations
1.2 Safety of machinery in Europe
Systems for executing safety-related control
functions
A
Non-electrical (e.g. hydraulic, pneumatic)
B
Electromechanical (e.g. relay and/or basic
electronics)
C
Complex electronics (e.g. programmable
electronics)
D
A Typicals combined with B Typicals
E
C Typicals combined with B Typicals
F
C Typicals combined with A Typicals
or
C Typicals combined with A Typicals and B
Typicals
"X" indicates that the point is covered by this Typical.
Comment 1:
Designated architectures are described in Annex B of EN ISO 13849-1 and provide a simplified basis for the quantification.
Comment 2:
For complex electronics: Using designated architectures in compliance with EN ISO 13849-1 up to PL = d or every
architecture in compliance with EN 62061.
Comment 3:
For non-electrical systems: Use components that comply with EN ISO 13849-1 as sub-systems.
22
EN ISO 13849-1
X
Restricted to the designated
architectures (see comment 1)
and max. up to PL = e
Restricted to the designated
architectures (see comment 1)
and max. up to PL = d
Restricted to the designated
architectures (see comment 1)
and max. up to PL = e
Restricted to the designated
architectures (see comment 1)
and max. up to PL = d
X
See comment 2
EN 62061
Not covered
All architectures and max. up to
SIL 3
All architectures and max. up to
SIL 3
X
See comment 3
All architectures and max.
up to SIL 3
X
See comment 3
Safety Integrated