Connecting
4.10 Routing
4.10.2

Routing on SIMOTION D (SINAMICS integrated)

S7 routing to the internal PROFIBUS on SINAMICS Integrated
All SIMOTION D have an integrated SINAMICS drive control. To be able to access drive
parameters, the telegrams must be routed from the external SIMOTION D interfaces to the
internal PROFIBUS DP. S7 routing can be used to access the integrated PROFIBUS. Here,
the internal PROFIBUS DP forms a separate subnet. This must be especially taken into
account for the communication to several routing nodes.
Additional references
You will find more information on routing and the differences between IP and S7 routing in the
SIMOTION Communication System Manual.
94
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
SIMOTION D4x5-2