Commissioning (software)
7.5 Additional information on configuring the SINAMICS Integrated
Remember that the 6 CU_Link DOs have to share this one parameter set in the DO CU_I.
Figure 7-37
Interconnection on the SINAMICS Integrated
Transfer parameters p850x/r851x (DO CU_I)
Parameters p8500-p8505 and r8510-r8515 of the Control Unit (DO CU_I) are so-called transfer
parameters. This means that a signal, for example, at the binector input p8500[0] is made
available at the binector output p8510[0] and can be interconnected further from there.
244
1
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
SIMOTION D4x5-2