Table A-3
Axis measuring system no.
Drive-related (local measur‐
ing input)
Measuring input number
Detailed information can be found in the
Measuring Inputs Function Manual.
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Configuration of drive-related I/Os (without symbolic assignment)
Local measuring inputs, configuration of the TO measuringInput
Under axis measuring system number, enter the number of the used
encoder system (namely, encoder 1, 2 or 3). Encoder system 1 is the
default setting.
Activate the checkbox when a local measuring input is used.
Enter here which measuring input is used (namely, 1 or 2). Input 1 is the
default setting.
A.3 Configuring local measuring inputs