Restoring Data With Switch Position "1" Or "A; Back Up Diagnostic Data And Non-Volatile Simotion Data Via The Web Server - Siemens SIMOTION D4x5-2 Commissioning And Hardware Installation Manual

Hide thumbs Also See for SIMOTION D4x5-2:
Table of Contents

Advertisement

Diagnostics
9.2 Diagnostic data and non-volatile SIMOTION data
9.2.4.2

Restoring data with switch position "1" or "A"

Procedure
To restore the non-volatile SIMOTION data, proceed as follows:
Step
Switch position "1"
1.
Insert the CF card into the new SIMOTION D4x5‑2. The SIMOTION D4x5‑2 must be switched off!
2.
Set the service selector switch to "1."
The position of the mode switch is not relevant, i.e. the
set operating mode remains unchanged.
Service selector switch (position 1)
3.
Switch the SIMOTION D4x5‑2 on.
4.
Restoration is started automatically.
5.
Once restoration has been completed, the module will start up automatically.
6.
Switch the module off and turn the service selector switch back to "0."
7.
Switch the SIMOTION D4x5‑2 on again.
9.2.5

Back up diagnostic data and non-volatile SIMOTION data via the web server

SIMOTION devices provide a web server with already prepared standard web pages. These
pages can be displayed via Ethernet using a commercially available browser. Additionally, you
have the option of creating your own HTML pages and incorporating service and diagnostic
information.
Diagnostic data and non-volatile SIMOTION data can be backed up via the web server. The
home page of the web server is opened by entering the IP address of the SIMOTION device
in the address line of the browser; e.g. http://169.254.11.22
This opens the home page of the web server. To back up diagnostic data and non-volatile
SIMOTION data, call the "Diagnostic files" page from the "Diagnostics" menu.
406
Switch position "A" (as of V4.4)
Set the service selector switch to "A."
The position of the mode switch is not relevant, i.e. the
set operating mode remains unchanged.
Service selector switch (position A)
Switch the SIMOTION D4x5‑2 on.
The flickering green SF LED indicates that restoration
is requested via position "A."
Turn the service selector switch to "1" to start restoration.