7.3 Performing an online configuration for the D4x5-2
To perform an online configuration, you must establish an online connection to the
SIMOTION D4x5‑2. In this case, no connection can yet be established to the SINAMICS
Integrated. An appropriate message is output. Once the hardware configuration has been
loaded to the target device, an online connection to the SINAMICS Integrated is established
automatically. Proceed as follows:
1. Save and compile the project.
2. Establish an online connection.
3. Select the SIMOTION D4x5‑2 device in the project navigator.
4. Use the "Download CPU / drive unit to target device" function to download the
SIMOTION D4x5‑2 to the target device. The connection to the SINAMICS Integrated is
established automatically.
Result
You can now run automatic configuration on the SINAMICS Integrated.
See Section Starting the automatic configuration (Page 204).
Additional references
Further information about establishing an online connection to the programming device/PC
can be found in the following documentation:
SIMOTION SCOUT Configuration Manual
SIMOTION SCOUT Online Help
● SIMOTION Utilities & Applications FAQs
SIMOTION Utilities & Applications is part of the scope of delivery of SIMOTION SCOUT.
● FAQOnline connection to SIMOTION
view/22016709)
7.3.3

Starting automatic configuration

Requirements
You have activated the online connection with the SINAMICS Integrated.
204
(https://support.industry.siemens.com/cs/ww/en/
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B