Commissioning (software)

7.6 Testing a drive with the drive control panel

7.6
Testing a drive with the drive control panel
Introduction
You can test a configured drive with the drive control panel, where you can specify a speed
and adjust it with a scaling factor. The drive control panel should only be used for
commissioning.
Requirements
● The project has been downloaded to the target system.
● SIMOTION SCOUT is in online mode.
● The drive is not being used by a current project in RUN mode.
Testing a drive with the drive control panel
1. Change to the configured drive in the Project Navigator and open the drive control panel
by selecting "Commissioning" > "Control panel". The drive control panel opens in the detail
view.
Figure 7-43
2. To display the control area and axis diagnostics, click the "Show/hide control area" and
"Show/hide diagnostics area" buttons.
254
WARNING
Danger to life from unexpected movement of driven machine parts
Make sure this presents no hazard to personnel or property.
Drive control panel
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B