Siemens SIMATIC Ident Function Manual page 84

Rfid systems. ident profile, add-on instruction for rockwell systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Configuring the instructions
4.6 Programming the Ident profile
Byte
Value
Bytes
No. of tran-
13...14
sponders
Byte 15
field_on_
control
84
RFID system Meaning
Value
transmit power
0x00
0x01
...
0x09
0x0A
0x0B
(...F)
RF300
The reader is basically intended for multitag operation, which is, however, not
currently released.
Maximum number of transponders that can be processed at the same time in the
antenna field. Currently permitted values "1".
RF600
Number of transponders expected in the antenna field.
Permitted values:
0x01 ... 0x28 for RF620R
0x01 ... 0x50 for RF630R with 2 antennas (SET-ANT = 0x03)
0x01 ... 0x28 for RF630R with 1 antenna (SET-ANT = 0x01 or SET-ANT =
0x02).
The value specified here defines the maximum expected number of transponders
to be read (EPC-ID) in the inventory.
The value does not restrict the number of transponders to be processed in the
antenna field. To allow an efficient inventory of transponders in the antenna field,
the values given here should not deviate from the maximum number of transpond-
ers expected in the antenna field by more than approx. 10%.
RF200,
0x00 (reserved)
RF300
RF600
"field_ON_control" sets the communications speed (fast/slow) and Tag Hold
(ON/OFF).
Bit
Description
0 ... 1
Speed
Reader parameter assignments that have been optimized depending on
the application are made available via the speed:
2 ... 4
Reserved
5
Tag hold
RF630R
radiated power (internal antenna)
ETSI
dBm / (mW)
dBm /
(mW)
ERP
18 / (65)
18 / (65)
19 / (80)
19 / (80)
...
...
27 / (500)
27 / (500)
27 / (500)
28 / (630)
27 / (500)
29 / (800)
0x00 = Fast detection
0x02 = Slower, more reliable detection
0x00 = OFF
0x01 = ON
Ident profile, Add-on instruction for Rockwell systems
RF620R
FCC
CMIIT
dBm /
dBm / (mW)
(mW)
ERP
EIRP
20 / (105)
18 / (65)
21 / (130)
19 / (80)
...
...
29 / (795)
27 / (500)
30 / (1000)
28 / (630)
31 / (1260)
29 / (800)
Function Manual, 01/2019, C79000-G8976-C410-03
RF620R
transmit
power
dBm / (mW)
18 / (65)
19 / (80)
...
27 / (500)
27 / (500)
27 / (500)

Advertisement

Table of Contents
loading

Table of Contents