Error mes-
Description
sage
(hex)
0xE1FE84
General transponder error
0xE1FE85
The transponder has too little power to execute the command.
0xE2FE01
Field disturbance on reader
Reader is receiving interference pulses from the environment.
External interference field. The interference field can be detected with the "inductive field indicator"
of the STG.
The distance between two readers is too short and does not correspond to the configuration guide-
lines
The connecting cable to the reader is disrupted, too long or does not comply with the specification
Too many transmit errors
The transponder was unable to receive the command or the write data from the communications mod-
ule correctly even after several attempts.
The transponder is positioned exactly in the limit area of the transmission window
Data transmission to the transponder is being affected by external interference
CRC sending error
The transponder reports CRC error frequently (transponder is positioned in the limit area of the
reader; transponder and/or reader has a hardware defect)
Only during initialization: CRC error on receipt of acknowledgement from transponder (cause as for
field interference on the reader)
When formatting, the transponder must be in the transmission window of the reader, otherwise a
timeout error will occur, in other words:
The transponder is located exactly in the limit area of the transmission window
The transponder is consuming too much power (defective)
Bad FORMAT parameter setting for transponder EEPROM
RF600:
No ETSI channel free
Wrong communications standard selected in the "INIT" command
Bad expert parameter
Power check of the ETSI wireless profile is incorrect
0xE2FE02
More transponders are located in the transmission window than can be processed at the same time by
the reader.
RF620R/RF630R: Transponder power supply close to limit.
Increase the antenna power or reduce the distance to the transponder.
0xE2FE81
There is no transponder with the required EPC-ID in the transmission window or there is no transponder at
all in the antenna field.
0xE2FE82
The requested data is not available.
0xE2FE83
The transponder signals a CRC error.
0xE2FE84
The selected antenna is not enabled.
0xE2FE85
The selected frequency is not enabled.
0xE2FE86
The carrier signal is not activated.
0xE2FE87
There is more than one transponder in the transmission window.