Table 4- 51
Parameter
CMD
OFFSETBUFFER
ATTRIBUTES
INVENTORY_DURATION
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
INVENTORY
Value / description
0x69
Offset in the "RXREF" receive buffer
Identifier of the status modes / possible entries:
RF68xR:
0x80 ≙ inventory with brief transponder information
0x81 ≙ inventory with a lot of transponder information
0x86 ≙ Presence mode on
0x87 ≙ Presence mode off
RF620R/RF630R:
0x82 ≙ read out the next data record
0x83 ≙ read handle ID when MOBY_mode ≙ 6 and EPC-ID when
MOBY_mode ≙ 7
0x85 ≙ read out handle IDs and EPC-IDs sorted in descending
order according to the mean RSSI value
0x91 ≙ read out handle IDs sorted in descending order according
to the maximum RSSI value
0x92 ≙ read out handle IDs sorted in descending order according
to read frequency
0xA0 ≙ read out first entries from Black List
0xA1 ≙ read out further entries from Black List
RF300:
0x00 ≙ list of all tags with UID
Only for 0x80 and 0x81:
Duration
Period of time or number of inventories or number of "Observed"
events
Example:
0x00 ≙ no inventory
0x01 ≙ one inventory
Configuring the instructions
4.6 Programming the Ident profile
73