Siemens SIMATIC Ident Function Manual page 101

Rfid systems. ident profile, add-on instruction for rockwell systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Tags
Chip type
RF680T
NXP G2XM 00 - 3F
RF682T
NXP
UCode
DNA
The user area also applies to the readers RF61xR/RF650R/RF68xR in memory bank 3.
1)
Uses User Memory Indicator (UMI).
2)
The EPC memory area of the Alien Higgs chips can be increased at the cost of the user memory. You will find further
3)
information in the relevant transponder sections.
Address spaces of the transponder variants for RF61xR/RF650R/RF68xR
With the new readers RF61xR/RF650R/RF68xR, the user data, TID, EPC and passwords
are read out via the relevant memory banks. To read out the required data, the relevant
memory bank must be selected.
The table above shows the area and length of the user data ("USER" column). You can read
out the EPC-ID using an inventory command. As an alternative, you can also read out the
EPC-ID using a Read command to memory bank 1, start address 0x04.
Figure 4-33
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
User
EPC
1)
[hex]
Area /
Area / length
length
(max. and default)
FF00-FF1D / 240
64
bits
bytes
FF00-FF0B / 96 bits
00 -
FF00-FF38 / 448
17F
bits
384
FF00-FF0B / 96 bits
bytes
Memory configuration
TID
(read only)
Access
Area / length
read/
FFC0-FFC7
write
8 bytes
read/
FFC0-FFCB
write
12 bytes
Configuring the instructions
4.8 Transponder addressing
RESERVED
Special
(passwords)
Area / length
KILL-PW
FF80-FF87
LOCKED
8 bytes
FF80-FF87
LOCKED
8 bytes
Lock func-
tion
Yes
Yes
101