Siemens SIMATIC Ident Function Manual page 51

Rfid systems. ident profile, add-on instruction for rockwell systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Table 4- 33
ATTRIBUTE "0x82" ("IID_TAG_STATUS_82_RF300" data type)
Name
reserved
status info
UID
LFD
FZP
FZA
ANWZ
reserved1
Table 4- 34
ATTRIBUTE "0x83" ("IID_TAG_STATUS_83_ISO" data type)
Name
reserved
status info
UID
MDS Type
IC version
size HB
size LB
lock state
block size
number of block
Table 4- 35
ATTRIBUTE "0x84" ("IID_TAG_STATUS_84_RF600" data type)
Name
reserved
status info
UID
antenna
RSSI
last observed hour
last observed min
last observed sec
last observed channel
EPC length
reserved1
The internal time stamp of the internal reader clock that relates to this event is output. The internal reader clock is not
1)
synchronized with UTC.
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
Type
Comment
SINT
SINT
MDS status mode
SINT[8]
SINT
Magnetic flux density: correlation between limit-value
SINT
Error counter passive: distortion without communication
SINT
Error counter active: distortion during communication
SINT
Presence counter: measure value for presence time
SINT[3]
Type
Comment
SINT
SINT
MDS status mode
SINT[8]
SINT
Type of MDS
SINT
Chip version
SINT
Size of Memory (high Byte)
SINT
Size of memory (low Byte)
SINT
Write protection status EEPROM
SINT
Size of a block in addressable memory
SINT
Number of blocks in addressable memory
Type
Comment
SINT
SINT
MDS status mode
SINT[8]
SINT
Antenna which has observed the MDS
SINT
RSSI value
SINT
Last observed time hour
SINT
Last observed time minute
SINT
Last observed time seconds
SINT
Last observed time channel
SINT
EPC-Length
SINT
Configuring the instructions
4.5 Programming add-on instructions
51