F286
Stopping Time at Stop Limit-Switch DOWN
Program  Crane/Hoist  Limit Switch Control
A Stop command is initiated upon activation of the Lower-Limit Stop Limit-
Switch.
This parameter sets the Decel rate to be used upon activation of the Lower-
Limit Stop Limit-Switch.
Preset Speed 8
Program  Frequency  Preset Speeds
This parameter assigns an output frequency to binary number 1000 and is
identified as Preset Speed 8. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
information on this parameter).
Preset Speed 9
Program  Frequency  Preset Speeds
This parameter assigns an output frequency to binary number 1001 and is
identified as Preset Speed 9. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
information on this parameter).
Preset Speed 10
Program  Frequency  Preset Speeds
This parameter assigns an output frequency to binary number 1010 and is
identified as Preset Speed 10. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
information on this parameter).
Preset Speed 11
Program  Frequency  Preset Speeds
This parameter assigns an output frequency to binary number 1011 and is
identified as Preset Speed 11. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
information on this parameter).
Preset Speed 12
Program  Frequency  Preset Speeds
This parameter assigns an output frequency to binary number 1100 and is
identified as Preset Speed 12. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
information on this parameter).
136
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Direct Access Number — F286
Parameter Type — Numerical
Factory Default — 1.5
Changeable During Run — No
Minimum — 0.0
Maximum — 25.0
Units — Seconds
Direct Access Number — F287
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
F018
for additional
Maximum — Upper Limit (F012)
Units — Hz
Direct Access Number — F288
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower Limit (F013)
F018
for additional
Maximum — Upper Limit (F012)
Units — Hz
Direct Access Number — F289
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
F018
for additional
Maximum — Upper Limit (F012)
Units — Hz
Direct Access Number — F290
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
F018
for additional
Maximum — Upper Limit (F012)
Units — Hz
Direct Access Number — F291
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
F018
for additional
Maximum — Upper Limit (F012)
Units — Hz
ACE-tronics G9 ASD Installation and Operation Manual
F291