F017
Motor Overload Protection Configuration
Program  Protection  Overload
This parameter is used to protect the motor from an over-current condition. The
type of motor being used and the Overload/Stall setting is selected here to
better match the application.
This parameter setting may extend the Over-Voltage Stall time settings.
This parameter may be affected by the setting of the Power Running Stall
Continuous Trip Detection Time (F452).
Settings:
Overload Trip without Stall
Overload Trip with Stall
No Overload without Stall
Stall Only
V/f Motor-Overload without Stall
V/f Motor-Overload with Stall
V/f Motor-No Overload without Stall
V/f Motor-Stall Only
86
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Direct Access Number — F017
Parameter Type — Selection List
Factory Default — Overload Trip