Chapter 5 Connectivity Status
5.7 Host-LU QoS
The following items are displayed in the Main area:
Port
The location information of the target port is displayed.
Type
The port type (fixed to "FC") is displayed.
Bandwidth Limit
The maximum performance of the target port is displayed in IOPS (throughput value). If the bandwidth
limit has not been configured (the bandwidth has not been limited), "Unlimited" is displayed.
Performance Monitoring
-
State
The status of performance monitoring for the host is displayed.
Active
Stopped
-
Start Time
-
Stop / Collect Time
The start time and the end time for performance monitoring are displayed.
YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Date (01 - 31), hh: Hour (00 -
23), mm: Minute (00 - 59), ss: Second (00 - 59))
The displayed time varies depending on how the performance monitoring is started or ended.
Before monitoring is started (*1)
"State" for performance monitoring is "Stopped". "-" (hyphens) are displayed for "Start Time" and
"Stop Collect Time".
Monitoring is started
"State" for performance monitoring is changed from "Stopped" to "Active". The time when
performance monitoring was started is displayed for "Start Time". The time when the performance
information is obtained is displayed for "Stop / Collect Time".
Monitoring is started while the monitoring session has already been started
"State" for performance monitoring is "Active". The last time when performance monitoring was
started is displayed for "Start Time". The time when the performance information is obtained is
displayed for "Stop / Collect Time".
Monitoring is stopped
"State" for performance monitoring is changed from "Active" to "Stopped". The last time when
performance monitoring was started is displayed for "Start Time". The time when performance
monitoring is stopped is displayed for "Stop / Collect Time".
Monitoring is stopped while the monitoring session has already been stopped
"State" for performance monitoring is "Stopped". The last time when performance monitoring was
started is displayed for "Start Time". The first time when performance monitoring was stopped is
displayed for "Stop / Collect Time".
*1:
When the start time is "0", "-" is displayed for "Start Time" and "Stop / Collect Time".
If performance monitoring is restarted during an active performance monitoring session, the
performance information that is already obtained is deleted and the collection of performance
information starts again.
When performance monitoring is not being performed after the ETERNUS DX/AF is started.