Vco Free-Running Frequency Adjustment; Encoder Output Level Adjustment - Sony BRC-300 Service Manual

3ccd color video camera / optical multiplex unit
Hide thumbs Also See for BRC-300:
Table of Contents

Advertisement

3-4. BRU-300/300P Electrical Alignment
3-4-3. VCO Free-Running Frequency
Adjustment
Adjustment Procedure
1. Remove the cover panel. (Refer to Section 1-4-1.)
2. Check that S3001-2 on the MC-66 board is set as
follows:
NTSC (BRC-300): OFF
PAL (BRC-300P): ON
3. Set S3501-3 and S3501-4 on the MC-66 board to ON.
4. Connect the tools and equipment, referring to Section
3-4-2.
5. Turn on the power of all the equipment, and warm
them up for about 20 minutes.
D4401 on the MC-66 board lights and "EVR_BRU
no:001 data:xxx" will be displayed.
6. Adjust "data" using the UP and DOWN switches
(S4803 and S4804) so that the value on the frequency
counter satisfies the specification.
Adjustment item:
Data of EVR_BRU no:001
3579545 ± 5 Hz (NTSC)
Specification:
4433618 ± 5 Hz (PAL)
7. Perform "3-4-4. Encoder Output Level Adjustment".
S3001
MC-66 BOARD (SIDE A)
CN-2548 BOARD (SIDE A)
3-34

3-4-4. Encoder Output Level Adjustment

n
Before this adjustment, perform "3-4-3. VCO Free-
Running Frequency Adjustment".
Adjustment Procedure
1. Press the ADJ switch S4802 on the CN-2548 board to
2. Adjust "data" using the UP and DOWN switches
3. Turn off the power of all the equipment.
4. Return S3501-3 and S3501-4 on the MC-66 board to
5. Reattach the cover panel. (Refer to Section 1-4-1.)
S3501
S4803
S4801
S4802
S4804
display "EVR_BRU no:002 data:xxx".
(S4803 and S4804) so that Y waveform level A on the
waveform monitor satisfies the specification.
Adjustment item:
Data of EVR_BRU no:002
A = 100 ± 1 IRE (NTSC)
Specification:
A = 700 ± 7 mV p-p (PAL)
A
OFF.
BRC-300/300P
BRU-300/300P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brc-300pBru-300Bru-300p

Table of Contents