12. Remove the three screws, and remove the prism
assembly.
13. Unsolder the CD-389S board from the prism assembly,
and remove the CD-389S board and three CCD covers.
14. Remove the two CD flexible cushions from the CD-
389S board.
PM1.7 x 7
Prism assembly
PM1.7 x 7
CD-389S board
Unsolder
Unsolder
CD flexible cushions
Unsolder
2-4
CCD cover
Prism assembly
CCD covers
Installation
15. Reassemble the camera assembly in the reverse order
from steps 7 to 14.
m
. Replace the CD flexible cushions with new ones.
. When reattach the CCD covers to the prism assem-
bly, pay attention not to mistake the orientation of
the CCD covers.
. When reattaching the three heat sinks to the board
chassis, insert each heat sink into each hole (Void
between the prism assembly and CCD cover) in the
figure on the previous page.
16. Perform the BRC-300/300P camera block electrical
alignment. (Refer to Section 3-2.)
17. Reassemble the unit in the reverse order from steps 1
to 6.
BRC-300/300P
BRU-300/300P