3-2. BRC-300/300P Camera Block Electrical Alignment
3-2-7. Data Initialization of Pages 8, A, C, D,
E, F, 1E, 1F
After replacing the IF-110 board, VISCA CPU (IC403/IF-
110 board), or VC-343 board, initialize the page data.
Initialization Procedure
1. Date initialization of pages A and D
2. Date initialization of pages 8 and C
3. Date initialization of pages E, F, 1E, and 1F
1. Date initialization of pages A and D
n
If "Date initialization of pages A and D" is performed, all
data of the page A and page D will be initialized. (It is
impossible to initialize a single page.)
Adjusting page
Adjusting address
A
00 to FF
D
00 to 7F
Initializing method
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
3
2
00
4
2
01
5
2
02
6
2
00
29
7
2
01
29
3-10
Set the data.
Set the data.
Set the following data.
55 (NTSC)
51 (PAL)
Set the data, and press
PAUSE button.
55 (NTSC)
51 (PAL)
Check that the data changes to
"01".
Set the data.
Set the data, and press
PAUSE button.
2. Date initialization of pages 8 and C
m
. If "Date initialization of pages 8 and C" is performed, all
data of the page 8 and page C will be initialized. (It is
impossible to initialize a single page.)
. After initializing the data of pages 8 and C, perform the
adjustments in Sections 3-2-8 and 3-2-9 again.
Adjusting page
Adjusting address
8
00 to A3
C
10 to FF
Initializing method
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
3
3
81
4
3
80
0C
5
3
80
Set the data.
Set the data.
Check that the data is "00".
Set the data, and press
PAUSE button.
Check that the data changes to
"1C".
BRC-300/300P
BRU-300/300P