Function Diagrams And Parameters - Siemens Sinamics S120 Function Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Basic functions
6.10 Armature short-circuit braking, DC braking
Using parameter p0491, responses to encoder faults of a motor encoder can be set (F07412
and many F3yxxx, y = 1, 2, 3).
Note
Motor type change
If the preconditions for armature short-circuit braking or DC braking are no longer satisfied
after a motor type has been changed (see p0300), then those modified parameters that have
armature short-circuit braking or DC braking as a response (e.g. p2100, p2101 or p0491) are
set to the factory setting.
Note
Deselecting armature short-circuit or DC braking
Armature short-circuit or DC braking cannot be deactivated using parameter p1231, as long
as a response parameterized with p2100, p2101 or p0491 has a fault condition.
6.10.4

Function diagrams and parameters

Function diagrams (see SINAMICS S120/S150 List Manual)
● 7014 External Armature Short-Circuit (EASC, p0300 = 2xx or 4xx)
● 7016 Internal Armature Short-Circuit (IASC, p0300 = 2xx or 4xx)
● 7017 DC brake (p0300 = 1xx)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● r0046.0...31 CO/BO: Missing enable signals
● p0300[0...n] motor type selection
● p0347[0...n] motor demagnetization time
● p0491 motor encoder fault response ENCODER
● r0722.0...21 CO/BO: CU digital inputs, status
● r0723.0...21 CO/BO: CU digital inputs, status inverted
● p0728 CU set input or output
● p0738 BI: CU signal source for terminal DI/DO 8
● p0745 BI: CU signal source for terminal DI/DO 15
● p0748 CU invert digital outputs
● p1226[0...n] standstill identification (zero speed) speed threshold
● p1230[0...n] BI: Armature short-circuit/DC braking activation
256
to
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Drive functions