Siemens Sinamics S120 Function Manual page 89

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Table 3- 3
Example of a PT2 filter
STARTER filter parameters
Characteristic frequency f
Damping D
0.7 dB
N
Band-stop with infinite notch depth
Table 3- 4
Example of band-stop with infinite notch depth
STARTER filter parameters
Blocking frequency f
= 500 Hz
Sp
Bandwidth (-3 dB) f
= 500 Hz
BB
Notch depth K = -∞ dB
Reduction Abs = 0 dB
Simplified conversion to parameters for general order filters:
● Reduction or increase after the blocking frequency (Abs)
● Infinite notch depth at the blocking frequency
● Numerator natural frequency f
● Numerator damping D
● Denominator natural frequency f
● Denominator damping:
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Amplitude log frequency curve
500 Hz
N
Amplitude log frequency curve
= 0
Z
= f
Z
Sp
= f
N
Sp
Servo control
3.7 Current setpoint filters
Phase frequency curve
Phase frequency curve
87