Siemens Sinamics S120 Function Manual page 788

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Basic information about the drive system
12.14 Write and know-how protection
8. When powering up, the Control unit checks the new serial numbers and deletes the
9. After it has powered up without any errors, the Control Unit is ready for operation. The
If the serial numbers do not match, then fault F13100 is output.
Example
This example shows you in which parameters of the expert list, the serial numbers of the
Control Unit and the memory card are located. The easiest way to obtain the serial numbers
is from the expert list of the Control Unit using the STARTER commissioning tool. To do this,
connect the programming device, on which the STARTER commissioning tool is running, to
the Control Unit that is switched on. Start the data connection between programming device
and the Control Unit ( "go online" ).
If you open the expert list of the Control Unit "online", then the serial numbers can be read
out of parameters r7758 and r7843. Make a precise note of the parameter values and for the
specific indices and give these values to your OEM. Do not omit any values or insert new
ones. Also the indices without any content are required to identify the serial number.
After, as user, you have received the new user data, transfer the data to the new memory
card using a read device. Then insert the memory card into your new Control Unit. When the
system is powered up for the first time, the serial numbers are automatically entered into
parameters r7758 and r7843. If the new serial numbers are identified as being correct, the
values of parameters p7759 and p7769 are deleted. The drive is ready.
Reading out the serial number of the Control Unit from the type plate or parameter r7758:
r7758 KHP Control Unit serial number
r7758[00] KHP Control Unit serial number
r7758[01] KHP Control Unit serial number
r7758[02] KHP Control Unit serial number
r7758[03] KHP Control Unit serial number
r7758[04] KHP Control Unit serial number
r7758[05] KHP Control Unit serial number
r7758[06] KHP Control Unit serial number
r7758[07] KHP Control Unit serial number
r7758[08] KHP Control Unit serial number
r7758[09] KHP Control Unit serial number
r7758[10] KHP Control Unit serial number
r7758[11] KHP Control Unit serial number
786
values p7759 and p7769 if they match.
know-how protection is active.
T
-
X
4
2
0
3
3
9
0
1
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2