Siemens Sinamics S120 Function Manual page 533

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Bit
10
Master control by PLC
Note:
This bit should not be set to "1" until PROFIdrive has returned an appropriate status via E_ZSW1.9 = "1".
11...15 Reserved
E_STW1_BM (control word for infeeds, metal industry)
See function diagram [2427].
Table 10- 20 Description of E_STW1_BM (control word for infeeds, metal industry)
Bit
Meaning
0
ON/OFF1
1
OFF2
Note:
Control signal OFF2 is generated by ANDing BI: p0844 and BI: p0845.
2
Reserved
3
Enable operation
4
Reserved
5
Infeed
6
Infeed
7
Acknowledge fault
Note:
Faults are acknowledged at a 0/1 edge via BI: p2103 or BI: p2104 or BI: p2105.
8...9
Reserved
10
Master control by PLC
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Meaning
10.1 Communication according to PROFIdrive
Remarks
1
Master control by PLC
This signal must be set so that the process data
transferred via PROFIdrive are accepted and
become effective.
0
No master control by PLC
Process data transferred via PROFIdrive are
rejected - i.e. assumed to be zero.
-
-
Remarks
0/1
ON
Pulse enable possible
0
OFF1
Reduce DC link voltage via ramp (p3566),
followed by pulse inhibit/line contactor open
1
No OFF2
Enable possible
0
OFF2
Immediate pulse suppression and switching on
inhibited
-
-
1
Enable operation
Pulse enable is present
0
Disable operation
Pulse inhibit is present
-
-
1
Inhibit motor operation
1
Inhibit regenerative operation
0/1
Acknowledge fault
-
-
1
Master control by PLC
This signal must be set so that the process data
transferred via PROFIdrive are accepted and
become effective.
Communication
Parameter
BI: p0854
-
Parameter
BI: p0840
BI: p0844
-
BI: p0852
-
p3532
p3533
BI: p2103
-
BI: p0854
531