10
Compressed air connection
The manual stopping valve lockable in closed
position (provided by customer) should be
installed on the machine's compressed air
supply.
The supply pipe should accept a pressure of
at least 1 Mpa (10 bar) (145 psi).
• Connection diameter : rapid action hose
coupling DN 6 (0.24") for hose Ø 6/8 mm.
Note : to avoid too big head losses, the
compressed air supply pipe should be
bigger in diameter than the coupling
diameter (DN 8 for example); in this case,
put a 6/8-8/10 adapter.
• Advised pressure : 550-700 kPa (5,5-7 bar)
• Minimum pressure: 550 kPa (5,5 bar)
(80 psi).
• Maximum pressure : 700 kPa (7 bar)
(102 psi).
• Consumption 280 l/h.
Air compressor
Some machines are supplied with an
integrated air compressor.
At fi rst start, it is necessary to turn off the
compressor manometer tap, wait until the
compressor reaches the pressure of 7 bars,
then re-open the valve.
• Regularly check the oil level (every 6
months)
and complete if necessary.
• Check the cleanliness of the intake fi lter,
clean
if necessary.
• Purge regularly the water separator tap.
24
Installation
(80-102 psi).
Compressed air
water separator
Service
Manual
D1670
tap
D1814
04102011/GB
51.2010