Electrolux IC4 4819 FFS Service Manual page 355

Feeder ironer folder & stacker
Table of Contents

Advertisement

Service
Manual
14. THERMIC FUSE FAULT
15. OVERHEAT SAFETY SWITCH
16. EXHAUSTING FAILURE
17. HEATING ERROR
18. MOTOR OVERHEATING
19. INVERTER ERROR
20. COM FAILURE
04102011/GB
06.2009
Troubleshooting
c : Overheating detection > 240°C.
s : Cool down the machine using wet linen and change
the thermal fuse once the machine is stopped.
c : A overheating > 215°C is occurred.
s : Decrease the heating temperature by ironing wet
linen.
c : Default of the gas burned evacuation.
s : Check the exhaust duct of gas burned and the
ventilation of the machine .
c : Contactors default, the contactors remain stuck
despite the heating is stopped.
s : Stop the machine using the main switch and turn
manually the cylinder in order to avoid to burn the
ironing strips.
c : xxxxxxxxxxxxxxxx.
s : xxxxxxxxxxxxxxxx.
c : xxxxxxxxxxxxxxxx.
s : xxxxxxxxxxxxxxxx.
c : Communication default between boards.
s : Check the communication wires of boards.
51
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic4 4825 ffsIc4 4832 ffs

Table of Contents