Emerg. Stop Active; Lack Of Compressed Air - Electrolux IC4 4819 FFS Service Manual

Feeder ironer folder & stacker
Table of Contents

Advertisement

51

EMERG. STOP ACTIVE

A emergency stop button is activated.
Check the reason why the emergency stop was
activated and only rearm the emergency stop
button afterwards.
Once the reason is defi ned, proceed as follows:
1. Carry out the required corrective actions.
2. Reset the emergency stop button(s) by
turning it/them anti-clockwise.
3. Press 'Validation' to start again the
machine.

LACK OF COMPRESSED AIR

A furtive drop of compressed air is detected.
Check:
the supply of the customer compressed
air,
if there is indeed a pressure of 5 bar at the
B1 pressostat,
the airtightness of the compressed air
circuit pipes.
Once the problem solved, press 'Validation' to
start again the machine.
6
Troubleshooting
01. EMERGENCY STOP ACTIVE
Release emergency stop
and start machine again
02. LACK OF COMPRESSED AIR
Check compressed air pressure (5 bars)
or contact your technician
Service
Manual