Testing the radio link

Testing the radio link
This section describes how to test the link when there is no radio communication, or
when it is unreliable, or when the data throughput rate is too low. It may be necessary
to test the ODUs at both ends of the link.

No activity

If there is no wireless activity, proceed as follows:
1
2
3
4
5
6
7
8
8-12
Select menu option Home and check Wireless Link Status on the System
Summary page.
Check that the firmware at each end of the link is the same version.
Check Range and Transmit Power.
Check Master/Slave Mode for each unit and ensure that one unit is
Master and the other unit is Slave.
Check that the link is not obstructed or the ODU misaligned.
Use the Channel Status web page at each end of the link to confirm that
there is a quiet wireless channel to use. Refer to
on page 7-19.
If there are no faults found in the configuration and there is absolutely no
wireless signal, retry the installation procedure.
If this does not work then report a suspected ODU fault to Motorola.
Chapter 8 Troubleshooting
Checking channel status
phn-2182_002v000
May 2011