Disconnecting an RJ45 and gland from a unit

Perform this task to disconnect the drop cable from an ODU or LPU. This procedure
contains illustrations of an ODU, but it applies in principle to both the ODU and the
LPU.
To disconnect the drop cable with a gland from a unit (LPU or ODU), proceed as
follows:
Remove the gland back shell.
1
2
Wiggle the drop cable to release the tension of the gland body.
When the tension in the glad body is released, a gap opens at the point
shown in red in the above photograph.
3
Unscrew the gland body.
4
Use a small screwdriver to depress the RJ45 locking tab.
5
Unplug the RJ45.
phn-2182_002v000
May 2011
Installing the drop cable and LPU
5-21