Installing And Grounding The Main Drop Cable; May 2011; Figure 5-9 Drop Cable With Rj45 And Gland - Motorola PTP 250 User Manual

Power over ethernet injector unit, poe power supply
Hide thumbs Also See for PTP 250:
Table of Contents

Advertisement

Installing the drop cable and LPU
Figure 5-9

Figure 5-9 Drop cable with RJ45 and gland

Installing and grounding the main drop cable

Perform this procedure to install the main drop cable, connect it to the ODU, and
ground it to the supporting structure.
To install and ground the main drop cable, proceed as follows:
1
Hoist the main drop cable up to the ODU using the hoisting grip and a
hoist line. When the cable is in position and the grip handle is fastened to
the supporting structure, remove the hoist line.
2
Connect the top end of the long drop cable to the ODU (PoE port), as
described in
Lay the main drop cable as far as the building entry point, ensuring there
3
is enough length to extend through the wall of the building to the LPU.
Attach the main drop cable to the supporting structure using cable ties
4
or cleats.
Ground the drop cable to the supporting structure at the points shown in
5
Figure 2-3
described in
5-18
shows the end of a drop cable fitted with an RJ45 plug and a gland.
Connecting an RJ45 and gland to a unit
(mast or tower installation) or
Making a drop cable ground point
NOTE
A mast or tower may require additional grounding points, as
specified in
Protection requirements for a mast or tower installation
on page 2-14.
Chapter 5 Installation
on page 5-19.
Figure 2-4
(wall installation), as
on page 5-22.