20.9
Creating a new block
Create INT blocks i you wish to make changes with the PLC user program.
Name
Author
Number of the
interrupt program
Data class
Comment
Note
Access protection
You have the option of protecting blocks that have been newly created against being
accessed.
Procedure
...
Turning
Operating Manual, 07/2010, 6FC5398-8CP40-0BA0
INT _100, INT_101
The number from the selection field "Number, interrupt program" is
taken for the name of the INT block.
A maximum of 48 characters is permitted.
100
101
Individual
A maximum of 100 lines and 4096 characters are permitted.
1.
The ladder diagram display (LAD) is opened.
2.
Press the "Program block" softkey to open the list of program blocks.
3.
Press the "Add" softkey.
The "Properties" window appears.
4.
Enter the name of the author, number of the INT block and, if required,
a comment.
The data class of the block is specified.
5.
Press the "OK" softkey to transfer the block to the list.
Ladder Viewer and Ladder add-on (828D only)
20.9 Creating a new block
665