Deactivate Transformation: Trafoof - Siemens sinumerik 840d Programming Manual

Hide thumbs Also See for sinumerik 840d:
Table of Contents

Advertisement

08.97
7
840D
NCU 572
NCU 573
7.6

Deactivate transformation: TRAFOOF

Programming
TRAFOOF
Explanation of the commands
TRAFOOF
Function
When the TRAFOOF command is issued, all active
transformations and frames are deactivated again.
Frames that are required after this must be
programmed again to be activated.
Please note:
The same restrictions apply for deselection of a
transformation as for its activation (see preceding
Section "Supplementary conditions for selection of a
transformation")
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) − 04.00 Edition
7.6 Deactivate transformation: TRAFOOF
810D
840Di
Deactivates all active transformations/frames
Transformations
7
7-253