File and Program Management
3
3.5 Defining protection levels for user data (GUD)
840D
840D
NCU 571
NCU 572
NCU 573
Sequence
The access protection level is programmed with the
desired protection level in the relevant module
before any variable is defined.
Both vocabulary words must be programmed in a
separate block.
Example of a definition file with read/write access
protection (machine manufacturer):
%_N_GUD6_DEF
;$PATH=/_N_DEF_DIR
APR 5 APW 2
DEF CHAN REAL_CORRVAL
...
M30
3-136
FM-NC
810D
840Di
;Read/display with protection level
keyswitch position 2
;Write with protection level OEM_LOW
;Caution! This entry can alter the access
rights of the file itself (see above)
;
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) − 04.00 Edition
08.97