console of the
XSCF to confirm the completion of the command.
If you answer "yes" this command will HALT the XSCF when it
completes.
You will need to power cycle the system after the XSCF BOOT
STOP.
Do you really want to continue?
Continue?[yes/no](default no):yes
The initialization of XSCF will be started.
XSCF : all data clear (exclude SYSTEM ID data)
BACK UP : all data clear (exclude SYSTEM ID data)
XSCF will be automatically rebooted. Afterwards, XSCF will be
initialized.
Continue?[yes/no](default no):yes
Disabling IDIAG prompt complete
Setting FRUID-ROM to writable complete
Clear BB-ID complete
Backup common DB complete
Syncing file systems... complete
XSCF shutdown request was completed.
6.
Confirm that all LEDs on the operation panel are off.
7.
Remove the power cords from the power supply units.
8.
Change the BB-IDs to the correct settings.
For details, see
"4.1 Setting the ID (BB-ID) Identifying a
9.
Perform steps 3 to 8 for BB#01.
10. Connect the SCF cables and DUAL cables of BB#00 and BB#01.
11. Connect the power cords of all chassis to the power supply units.
12. Connect the system management terminal to the serial port of the master
XSCF.
13. Proceed with work by returning to
Chassis."
"6.3 Logging In to the
Appendix A Troubleshooting
XSCF."
321