Figure A-4 Mistaken settings for the BB-IDs of BB#00 and BB#01
1.
Remove the power cords of all chassis from the power supply units.
2.
Disconnect the SCF cables and DUAL cables of BB#00 and BB#01.
3.
Connect the system management terminal to the serial port of BB#00, and
connect the power cords to the power supply units.
4.
Log in to the XSCF by using the default user account and authentication
method.
For details, see
5.
Execute the restoredefaults -c factory command to return the entire system to
the factory default settings.
XSCF> restoredefaults -c factory
WARNING:
If this system does not have BACK UP, this command will set
all the user
settable XSCF configuration parameters to their default value
as they
were set when the system was shipped out.
Furthermore, this command will delete all logs in the intended
chassis XSCF.
Check the man page of this command before you run it.
Continue?[yes/no](default no): yes
You must check the following points.
1. Have the ability to power cycle the system.
2. Have access to the serial console and hold the serial
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
320
BB#03
BB#02
NG
BB#00
BB#01
NG
"6.3 Logging In to the
XSCF."